Max. BEC current at 25 °C |
A
|
Possibility of setting the voltage of BEC |
|
"One-way" mode |
|
Compatible with all types of feeding cells |
|
Max. peak current |
1000A
|
Operating voltage |
12 - 63 V
|
Very high resistance against overloading |
|
Possibility of cells temperature measuring (cells protection) |
|
Number of regulation steps |
2048
|
Possibility of setting RPM limits (motor protection) |
|
On-state switch (FETs) resistance at 25 °C |
2 mW
|
Dimensions |
see guide
|
Weight without power conductors |
1200 gram
|
Possibility of automatic setting of cut off voltage |
|
Power conductors cross-section to batt. / to mot. |
see guide
|
Manually set type of cells |
|
Servocable cross-section |
0.25 mm2
|
Possibility of manually set timing |
|
Possibility of design with external heatsinks |
|
Active free-wheeling circuit ON / OFF |
|
Possibility of design with external heatsinks + FAN |
|
External signalization of important states |
|
Possibility of WR version (full protection against water) |
|
Adjustable deceleration speed |
|
Software updates available through internet |
|
Software reversal of rotation |
|
Programming using PC |
|
False-start protection |
|
Temperature fuse of the controller |
|
Reversible controller (both-way mode) |
|
Setting of the range of neutral zone |
|
Telemetry (real-time back data transfer) |
|
Possibility of operation also with sensors motors |
|
Automatic Sensor Setting |
|
4 Memory Banks |
|
Number of A123 feeding cells |
5
|
Max. continuous current |
800A
|
Number of NiCd, NiMh feeding cells |
15
|
Available BEC / OPTO versions |
|
Plug and Play (functional immediately without the need for additional programming) |
|
Outstanding cells management |
|
Possibility of motor temperature measuring (motor protection) |
|
Motor PWM frequency |
8 kHz
|
Possibility of setting current limits |
|
Max. RPM |
200000
|
Dimensions with external capacitor |
see guide
|
Possibility of setting switching off voltage |
|
Weight incl. all conductors |
see guide
|
Possibility of manually set number of cells |
|
Length of the power conductors |
see guide
|
Automatically set timing |
|
Length of the servocable |
190 mm
|
Possibility of automatic setting of throttle limits |
|
Possibility of design with water-cooled heatsinks |
|
Possibility of connecting plane position lights and flashing lights |
|
Possibility of WP version (increased protection against water) |
|
Adjustable acceleration speed |
|
Possibility of design with ON/OFF switch (connected safely) |
|
Empty batt. behaviour - motor power reduction |
|
Reading-out of data from the controller using PC |
|
Masking of interference |
|
ICS-2 connector - super-fast PC connection link |
|
Current fuse of the controller |
|
ACR - Automatic Current Reduce |
|
Bidirectional "both-way" mode |
|
Possibility of switching reversible controller into "one-way" mode |
|
Internal Data Logger (data recorder) |
|
Real-time Monitoring (PC or other device) |
|